EN DE
Contact us
print page
Article No.: AAA20AA
Articlename: Autosampler AS 6.1L

Biocompatible analytical FPLC Autosampler


analytical HPLC autosampler with biocompatible flow path

The Autosampler AS 6.1L can inject from up to 768 positions when equipped with microtiter plates (either high or low formats) or from up to 108 standard 1.5 ml sample vials. Sample carryover is significantly minimized thanks to a highly-effective interior and exterior needle wash procedure. This autosampler is also fast and flexible: one complete sample injection cycle takes less than one minute, including needle wash. Three different injection modes are supported; “full loop filling” (highest precision and reproducibility), “partial loop filling” (variable volumes, e.g. for dilution series) and “µl pickup” (loss-free injection of extremely small sample volumes), allowing the user to optimize sample usage. The headspace pressure function prevents bubbles from forming in the vial during sample uptake. Precolumn derivatization is supported.
With biocompatible sample path.

Technical Data

Sample injection

Autosampler Flow Path Biocompatible
Maximum back pressure 345 bar
Vial/plate dimensions max. plate/vial height: 47 mm (incl. septa or capmat)
Injection volume range 0.1 µl - 10 ml depending on sample loop
Sample loop 100 µl
Dispenser syringe 250 µl
Headspace pressure built-in compressor, only for sample vials with septum
Switching time inj. valve < 100 ms
Piercing needle precision ± 0.6 mm
Sample tray cooling none
Vial detection missing vial/well plate detection by sensor
Needle wash programmable: wash between injections and wash between vials
Wetted materials

Tefzel® (ETFE), Glass, Teflon® (PTFE), Kel-F® (PCTFE), PEEK

Analytical performance

Injection modes full loop filling, partial loop filling and microliter pickup; PASA™ (pressure-assisted sample aspiration)
Injection precision RSD (Relative Standard Deviation):full loop filling: <0.3%partial loop fillings at injection volumes>5 µl: <0.5%microliter pickup at injections>5 µl: <1.0%
Sample carryover < 0,01 % under typical conditions using needle wash; < 0.005 % under special conditions with extended needle wash
Injections per vial max. 9 injections
Injection cycle time minimum 7 s from the same vial, 14 s from different vials;<60 s for>100 µl sample injection in all injection modes, incl. 300 µl needle wash
Analysis time max. 9 h, 59 min, 59 s

Communication

Inputs 2 programmable TTL inputs (next injection, freeze, stop)
Outputs 1 programmable relay output (inject marker, auxiliary, alarm)
Control Ethernet (LAN)
Interfaces LAN, analog

Technical parameters

Ambient conditions temperature range: 10–40 °C; 50–104 °F air humidity: 20 - 80%

General

Power supply 95–240 V AC
Dimensions 361 x 375 x 570 mm (W x H x D)
Weight 32 kg