GABI* is the latest technology μ-processor controlled gamma spectrometer. GABI* is assembled by modules of 19” format, which makes modification and service support very fast and easy. GABI* has high voltage unit for manual or automatic selection of the required detector operation. Inserting a suitable calibration source and running the automatic calibration program, GABI* is setting all parameters to an calibrated energy scale. Recalibration for compensation of any drift is quite easy, fast and fully automatic. GABI* has 2 simultaneous counting channels with 2 individually selectable energy thresholds each for setting an individual counting window for a particular nuclide. GABI* is counting the radiation events in an energy channel per selected interval time. The information of counts per time is transferred to GINA* program. The chromatogram is displayed live on screen. No overriding of ranges can happen. Peak integration, background subtraction, flow correction, absolute activity calculation etc can be performed manually or automatically. Limit-of-detection is determined for every ROI, displayed and printed. All data and parameters are stored under one identity code. GINA* can be installed as well in the background of the original HPLC-operation program and the user can use the operation program of the HPLC supplier as well as the advantages of GINA*.

Technical Data

Detection

Detector type Radioactivity detector
Version flow-through γ-radioactivity monitor
Detection channels 2

Communication

Inputs 7 analog input channels, -0.5 to +4.5 V, resolution 21 bit
Outputs RS232C, 2 analog outputs 0 to 1 V, resolution 20 bit
Control keyboard 16 touch sensetive keys, digital communication to pc, Gina* programm

Technical parameters

Ambient conditions Temperature range: 10 - 40 °C Humidity: below 70 % noncondensing

General

Power supply 230 V; 50 Hz
Dimensions 250 x 160 x 320 mm (W x H x D)

Software

Note Scintillation probe has to be additionally choosen.

Documents and more information

Do you need more details or a quote?

We are happy to help you

Technical data or prices are subject to change without notice. Prices may vary by country and do not include taxes, customs duties or delivery.
All trademarks are the property of their respective owners.Our general terms and conditions apply: www.knauer.net/terms

Follow us