HPLC 862 bar system with quaternary LPG pump and 3D diode array detector

HPLC 862 bar system with quaternary LPG pump and 3D diode array detector

Contact us
print page
Article No.: 986502200
Articlename: AZURA 862 LPG System DAD 2.1L

HPLC 862 bar system with quaternary LPG pump and 3D diode array detector


System Proposal

Eluent delivery

The Pump P 6.1L with LPG configuration has a new LPG valve for precise mixing efficiency of up to four eluents. The integrated degasser prevents air bubbles in the system. A mixing chamber is mounted on each Pump P 6.1L. This can be adapted to the respective application as required.

Sample Injection

The Autosampler 6.1L can inject 0.1 – 5000 µl to have a large flexibility. Using standard vials or two microtiter plates will give you a maximum sample capacity of up to 768 samples or 108 vials.

Column thermostating

The Column thermostat CT 2.1 is suitable for column thermostatization above and below room temperature. The instrument operates with a microprocessor controlled Peltier element for exact temperature settings.

Chromatography data system

KNAUER ClarityChrom® is a powerful, yet easy-to-use chromatography software for instrument control, data acquisition and data processing. It is an economical solution compared to other more complex chromatography software while still offering FDA 21 CFR Part 11 compliance.

Detection 

The detector DAD 2.1L features a novel light path and flow cell architecture with improved handling and excellent performance. This Diode array detector can be used in the wavelength range of 190-700 nm.

 

This AZURA Analytical system can be customized with several detectors

  • The diode array detector DAD 6.1L covers all conceivable applications with a spectral range of 190-1000 nm. With its novel light path and optimized flow cells, it is one of the most powerful devices on the market.
  • The detector MWD 2.1L is an 8 channel, sensitive multiwavelength detector combining high performance with easy handling at an affordable price. This multiwavelength detector can be used in the wavelength range of 190-700 nm.
  • The variable single wavelength UV/VIS detector UVD 2.1L comes with an installed deuterium lamp which covers a wavelength range from 190 to 750 nm. It is a competitively priced detector for routine HPLC applications including fast LC methods.
  • The fluorescence detector RF-20A provides world-class sensitivity for a wide range of applications in the wavelength range of 200 to 650 nm.
  •  

Customized configurations like combinations of several detectors are also available. Please contact us!

Key Features

Technical Data

Analytical system

Application area HPLC
Pump system Gradient
Gradient Quaternary LPG
Injection Autosampler
Detector Diode array detection DAD
Software ClarityChrom, Mobile Control
Pressure 862 bar
Column thermostat Yes

Documents and more information

Certified Quality 

KNAUER is known for the quality of its products and has been certified several times. We produce high-tech laboratory instruments for research, routine analysis and production.
See all Quality certificates

In addition, we have extended documentation about all our products, including CE Declarations of Conformity.
See all CE Declarations of conformity
 

Innovation and quality - since 1962. Made in Germany.

Do you need more details or a quote?

We are happy to help you

+49 30 809727-0

Mo – Fr
07:00 – 17:00 CE(S)T

sales@knauer.net

24 / 7
 

Technical data or prices are subject to change without notice. Prices may vary by country and do not include taxes, customs duties or delivery.
All trademarks are the property of their respective owners.Our general terms and conditions apply: www.knauer.net/terms

Follow us on: