EN DE

Basic Diode Array Detector for Liquid Chromatography and Process Technology

Contact us
print page
Article No.: ADC01
Articlename: AZURA Detector DAD 2.1L

Basic Diode Array Detector for Liquid Chromatography and Process Technology


190 - 700 nm, diode array detector

The AZURA DAD 2.1L is a highly competitive diode array detector which combines high performance with easy handling at an affordable price. A wide range of easily exchangeable cartridge flow cells make this device the right choice for fast, standard analytical, semi-preparative and preparative separations with bio-inert or stainless steel wetted parts. State-of-the-art total reflection flow cells (LightGuide technology) are available for this device providing maximum light throughput (due to total internal reflection) with minimal peak dispersion (due to the small cell volume) to guarantee an optimized S/N ratio. An optional fiber optics adapter offers the possibility to separate the flow cell spatially from the device and thus provides enhanced security for hazardous, explosive or toxic work processes, as well as protecting the device from leakages at high flow rates. The newly developed optical unit and intelligent temperature management ensure for maximum sensitivity combined with minimal baseline drift. Furthermore, easy frontal access and improved safety features enable effortless lamp replacement. This eases maintenance and guarantees short downtimes. The DAD 2.1L comes installed with a deuterium lamp which covers a wavelength range from 190 to 700 nm. This detector can be controlled with OpenLab® EZChrom, ClarityChrom®, Chromeleon® and PurityChrom® software, as well as with the Mobile Control software (stand-alone operation), via LAN or through analog input/output, allowing it to be integrated into almost any LC system.

Key Features

Technical Data

Detection

Detector type Diode array detector
Number of diodes 256
Pixel pitch 2 nm/diode
Detection channels 8 (Digital)/4 (Analog)
Light source Deuterium (D2) lamp with integrated GLP chip
Wavelength range 190 - 700 nm
Spectral bandwidth < 10 nm at Hα line (FWHM) /Note: digital bandwidth 1 - 32 nm
Wavelength accuracy ± 1 nm
Wavelength Repeatability ± 0.1 nm
Noise ± 5 µAU at 254 nm (ASTM E1657-98)
Drift 400 µAU/h at 254 nm (ASTM E1657-98)
Linearity > 2.0 AU at 274 nm (ASTM E1657-98)
Maximum data rate 100 Hz (LAN)/12.5 Hz (analog)
Flow cell Not included (see Accessories / Spare parts)
Time constants 0.00 / 0.01 / 0.02 / 0.05 / 0.1 / 0.2 / 0.5 / 1.0 / 2.0 / 5.0 / 10.0 s
Integration time Automatic
Wavelength verification Internal holmium filter and deuterium lines
Leak sensor Yes

Communication

Inputs Error (IN), Start (IN), Autozero
Outputs Events 1 - 2 (Relay and TTL compatible, respectively), Error (OUT), + 5 V, Valve + 24 V, Valve (OUT)
Analog outputs 4 x 0 - 5 V, 20 bit, offset adjustable
Control Mobile Control, software, event control, analog, terminal protocol
Interfaces LAN (RJ-45), RS-232 (SUB-D 9, service only), multi-pin connector, analog (RCA cinch connector)

Technical parameters

GLP Detailed report including lamp recognition, operating hours, lamp operating hours, number of lamp ignitions
Display Mobile Control (optional)
Ambient conditions Temperature range: 4 - 40 °C, 39.2 - 104 °F
Humidity: below 90 % non-condensing

General

Power supply 100 – 240 V, 50 – 60 Hz, 75 W
Dimensions 361 x 158 x 523 mm (W x H x D)
Weight 12.2 kg

Other

Note Flow cells are not included and must be ordered separately (see Accessories / Spare parts)

Documents and more information

Certified Quality 

KNAUER is known for the quality of its products and has been certified several times. We produce high-tech laboratory instruments for research, routine analysis and production.
See all Quality certificates

In addition, we have extended documentation about all our products, including CE Declarations of Conformity.
See all CE Declarations of conformity
 

Innovation and quality - since 1962. Made in Germany.

Do you need more details or a quote?

We are happy to help you

+49 30 809727-0

Mo – Fr
07:00 – 17:00 CE(S)T

sales@knauer.net

24 / 7
 

Technical data or prices are subject to change without notice. Prices may vary by country and do not include taxes, customs duties or delivery.
All trademarks are the property of their respective owners.Our general terms and conditions apply: www.knauer.net/terms

Follow us on: