Optional system components: configure your AZURA Bio LC system to your needs

Optional system components for solvent delivery, injection, analysis, detection and fraction collection.
Find the best system configuration with optional system components

The standard system configurations can be extended with optional system solutions. This flexibility allows the user to find the best configuration for each purification task, e.g. for the automation of your purification.

Configure your Assistant

Valves, pumps, and single wavelength detectors can be freely combined in the Assistant Module.

1. Buffer & sample selection

How many buffers do you need? How many different samples do you want to inject?

Selection Valve up to 50 ml/min

AWA10BD

Selection Valve over 50 ml/min

A5854

Sample/Buffer selection Assistant

AYELELEL

2. Bio LC Pump

What is your favorite flowrate? Do you need a gradient system?

Small isocratic FPLC Pump for integration into Assistant

DPG17BB
DPG17DC

Binary FPLC pump with or without degasser, 10 ml/min

APH65EB
APH68EB

Binary FPLC pump without degasser, 50 ml/min

APH68FB

Isocratic FPLC pump without degasser:10 or 50 ml/min

APH60EB
APH60FB

Quaternary FPLC pump with or without degasser 10 ml/min

APH64EB
APH69EB

Preparative FPLC pump, 100, 150, 500, 1000 ml/min

APE20KB
APE20LC
APE20MC
APE20NB

Ternary Gradient Module for preparative Pump up to 220 ml/min

AZZ10AB

Binary Gradient Module for preparative Pump up to 800 ml/min

AZZ00AA

3. Injection

How would you like to apply your sample?

Injection Valve up to 50 ml/min

AWA10AC

Injection Valve over 50 ml/min

AWA10AE

Sample Pump for integration into Assistant

DPG17BB
DPG17DC

Injection Assistant

AYECECBH up to 50 ml/min
AYEGEGBH over 50 ml/min

4. Column selection

How many columns do you need?

Column Selection Assistant for flow rates up to 50 ml/min

 

AYEIEILX

 

Column Selection Valve with Reverse Flow Option up to 50 ml/min

 


 
AWB00FC

Column Selection Assistant for flow rates over 50 ml/min

 

AYELELLX

 

Column Selection Assistant with Reverse Flow Option for flow rates over 50 ml/min

 

AYELELEG

 

Column Selection  Valve:

 

AWA10AC (for flow rates up to 50 ml/min)
AWA10AE (for flow rates above 50 ml/min)

 

5. Detection

How would you like to detect? Would you like to monitor your gradient? How much information do you need? 

Variable single wavelength UV Detector

ADA00

Variable single  UV Detector with fiber optics connector

ADA05

Multiwavelength Detector

ADB01

Conductivity monitor up to 100 ml/min

ADG30

pH Option

A70091

More detectors on demand

6. Fraction collection

How do you collect your sample?

Fraction Valve for large sample volumes, flowrate up to 50 ml/min

AWA10BB

Fraction Valve for large sample volumes, flowrate over 50 ml/min

AWA10BD

Fraction Collector Foxy R1

A59100
A59100-1
A59100-2
A59100-3
A59100-4

Fraction Collector Foxy R2

A59102
A591021